Recommendation

Avoid installing the camera facing a light source. Visitor images be unsatisfactory. We recommend installing the outdoor panel at a height of approximately 1.60 m.

1) Mounting and wiring of the outdoor panel

Run all cables through the rain shield.

Attach the rain shield to the wall/pillar.

 

Connect:

  • the monitor cable to the first two terminals of the outdoor panel: M+ on from the monitor to :
    • M+ on the outdoor panel
    • M- on the monitor to M- on the outdoor panel
  • the cable from the electric lock/strike plate to terminals L+ and L- on the outdoor panel.
  • the motorization cable to the dry contact output (COM and NO) of the outdoor panel

Note: To insert the wires into the terminals, using a screwdriver, press the square with the notch, insert the wires and release.

 

Position the outdoor panel within the rain shield.

 

Screw the outdoor panel to the rain shield using the Torx key provided.

 

4) Installing the name tag

  • Rotate the call button counterclockwise to the engraved mark, then remove it.
  • Remove the round membrane to access the name tag.
  • Write your name on the white label with a permanent marker and replace the label and its membrane in their housing.